Battery-Management-System [BMS]
für 10 zellige Akkupacks [10S] - Lithium
Eigenschaften:
|
No.
|
Test Item
|
Min.
|
Typ.
|
Max
|
Unit
|
|
1
|
Input Charging Voltage
|
41.8
|
42
|
42.2
|
V
|
|
2
|
Input Charging Current
|
|
15
|
20
|
A
|
|
3
|
Output Discharging Current
|
|
40
|
50
|
A
|
|
4
|
Over-Current Discharging Protection
|
40
|
45
|
50
|
A
|
|
5
|
Current Consumption
|
10
|
15
|
25
|
uA
|
|
6
|
Balance Current
|
40
|
45
|
50
|
mA
|
|
7
|
Balance Voltage
|
4.18
|
4.20
|
4.22
|
V
|
|
8
|
Over-Charge Protection Voltage
|
4.18
|
4.20
|
4.25
|
V
|
|
9
|
Over-Charge Protection Voltage Release
|
4.05
|
4.10
|
4.15
|
V
|
|
10
|
Over-Charge Protection Voltage Delay Time
|
1.0
|
1.5
|
2.0
|
S
|
|
11
|
Over-Discharge Protection Voltage
|
2.67
|
2.75
|
2.83
|
V
|
|
12
|
Over-Discharge Protection Voltage Release
|
2.9
|
3.0
|
3.1
|
V
|
|
13
|
Over-Discharge Protection Voltage Delay Time
|
1.0
|
1.5
|
2.0
|
S
|
|
14
|
Short Circuit Protection Release
|
Remove the load
|
|
15
|
Impedance
|
|
8
|
15
|
mO
|
|
16
|
Operating Temperature
|
-15
|
+25
|
+60
|
ºC
|
|
17
|
Storage Temperature
|
-20
|
+25
|
+70
|
ºC
|
Wie verlöte ich das BMS?
- Battery Negative (schwarz) an den Minus-Pol des Akkupacks
- Zellenabgriff B1- an den Minus-Pol des Akkupacks
- Zellenabgriffe B2 bis B10 der Reihe nach anlöten. Immer der Reihe nach anlöten!
- Den Minuspol der Anwendung löten Sie an P-
- Den Pluspol der Anwendung löten Sie direkt an den Pluspol des Akkupacks
- Ladegerät Minuspol wird an C- an das BMS angebracht
- Ladegerät Pluspol wird direkt am Pluspol des Akkupacks angebracht
Angaben zur Produktsicherheit
Herstellerinformationen:
AkkuPlus GmbH & Co. KG
Hauptstr. 22
Hessen
Burgwald, Deutschland, 35099
info@akkuplus.de
https://www.akkuplus.de
verantwortliche Person:
AkkuPlus GmbH & Co. KG
Hauptstr. 22
Hessen
Burgwald, Deutschland, 35099
info@akkuplus.de
https://www.akkuplus.de
| Versandgewicht: |
0,15 kg
|
| Artikelgewicht: |
0,15 kg
|