Battery-Management-System [BMS]
für 14 zellige Akkupacks [14S] - Lithium
Eigenschaften:
|
No.
|
Test Item
|
Min.
|
Typ.
|
Max
|
Unit
|
|
1
|
Input Charging Voltage
|
58.6
|
58.8
|
59.0
|
V
|
|
2
|
Input Charging Current
|
|
8
|
|
A
|
|
3
|
Output Discharging Current
|
|
20
|
|
A
|
|
4
|
Over-Current Discharging Protection
|
55
|
60
|
65
|
A
|
|
5
|
Current Consumption
|
10
|
15
|
25
|
uA
|
|
6
|
Balance Current
|
45
|
50
|
55
|
mA
|
|
7
|
Balance Voltage
|
4.16
|
4.18
|
4.20
|
V
|
|
8
|
Over-Charge Protection Voltage
|
4.21
|
4.25
|
4.3
|
V
|
|
9
|
Over-Charge Protection Voltage Release
|
4.0
|
4.15
|
4.2
|
V
|
|
10
|
Over-Charge Protection Voltage Delay Time
|
1.0
|
1.5
|
2.0
|
S
|
|
11
|
Over-Discharge Protection Voltage
|
2.42
|
2.5
|
2.58
|
V
|
|
12
|
Over-Discharge Protection Voltage Release
|
2.9
|
3.0
|
3.1
|
V
|
|
13
|
Over-Discharge Protection Voltage Delay Time
|
1.0
|
1.5
|
2.0
|
S
|
|
14
|
Short Circuit Protection Release
|
Remove the load
|
|
15
|
Impedance
|
|
8
|
15
|
mO
|
|
16
|
Operating Temperature
|
-15
|
+25
|
+45
|
ºC
|
|
17
|
Storage Temperature
|
-20
|
+25
|
+30
|
ºC
|