Battery-Management-System [BMS]
für 6 zellige Akkupacks [6S] - Lithium
Technische Daten:
|
No.
|
Test item
|
Criterion
|
|
1
|
Voltage |
Charging voltage |
DC:25.2V CC/CV |
| Balance voltage for single cell |
4.20±0.025V |
|
2
|
Current |
Balance current for single cell |
42±5mA |
| Current consumption |
=20µA |
| Maximal continuous charging current |
12A |
| Maximal continuous Discharging current |
12A |
|
3
|
Over charge Protection |
Over charge detection voltage |
4.325±0.025V |
| Over charge detection delay time |
0.5S—2S |
| Over charge release voltage |
4.0755±0.025V |
|
4
|
Over discharge protection |
Over discharge detection voltage |
2.50±0.05V |
| Over discharge detection delay time |
10-200mS |
| Over discharge release voltage |
2.9±0.05V |
|
5
|
Over current protection |
Over current detection voltage |
0.15±0.015V |
| Over current detection current |
50±10A |
| Detection delay time |
5ms—20ms |
| Release condition |
Cut load |
|
6
|
Short Circuit protection |
Detection condition |
Exterior short circuit |
| Detection delay time |
200-500us |
| Release condition |
Cut load |
|
7
|
Resistance |
Protection circuitry (MOSFET) |
=30mO |
|
8
|
Temperature |
Operating Temperature Range |
-40~+85 Cent. |
| Storage Temperature Range |
-40~+125 Cent. |